explosion proof balance
Precision Weighing Balances
Home > Sartorius > Explosion-proof, Intrinsically Safe Scales Sartorius Balances

Balances Search:

Cross reference an
old model with new

Mettler > Sartorius

Entire Sartorius Line

Micro (1-0.1µg)
Cubis Series
ME36-S Balance
CPA26P Balance
SE/ME Series
LE26P Balance
CP2P Series

Analytical (0.1-0.01mg)
Entris Balances
Practum Scales
Quintix Balances
Secura Scales
Cubis Series
Genius - Pro
LE - isoCAL
LA - Pro
CP - Standard
ED - Extend
AZ - Basic
GC - Gem
TE - Economy

Milligram (0.001g)
Entris Scales
Practum Balances
Quintix Scales
Secura Balances
Cubis Series
LE - isoCAL

LA - Pro
CP - Standard
ED - Extend
GK - Gem
AZ - Basic
BL Scales
TE - Economy
AY123 Scale
GC - Gem

Precision (0.01-0.1g)
Entris Balance
Practum Scale
Quintix Balance
Secura Scale
Cubis Series
LE - isoCAL

LA - Pro
CP - Standard
ED - Extend
AZ - Basic
TE - Economy
BL Portable
AY Scales
GW - Gem
GP - Gem

Legal for Trade
Diamond Scale
Pharmacy Scale

Portable (0.1-0.001g)
TE - Economy
GE - Gem
ELT Series
AY Scales

High Cap (16kg-64kg)
LE - isoCAL
LA - Pro
CP - Standard

Moisture Analyzers
MA160
MA37
MA100/MA50
MA150
MA35

Explosion-proof
FC-Ex Series

Bench Scales
Signum Scales
Midrics Scales
EA/EB Scales

Filter Balances
MSA2.7S x 0.1ug
MSA6.6 x 1ug
Quintix65 x 10ug
SE2F 2g x 0.1ug

ME5-F 5g x 1ug
CP2P-F 2g x 5ug
LA130S-F x 0.1mg

Industrial Scales
QC Washdown
Floor Scales

Mass Comparators
21g 0.001mg
10kg x 0.01mg
303kg x 1g
3,000kg x 10g

Used / Demo Units
Micro Balances
Analyticals

Accessories
Cal Weights
Mass Sets
Certified Weights
Specific Gravity
Printer
Static Eliminator
Winwedge Software
Weigh Dishes
Weigh Boats
Beakers
Titration Cups
Moisture Pans
Glassine Paper
AL Dishes
Weighing Canoes
Micro Dishes

Manufacturers
AdamLab
AND Weighing
CAS Scales
Chatillon
Health-o-Meter
Mettler Toledo
My-weigh
Ohaus
Sartorius
Scientech
SECA Medical
Troemner
Siltec
Tanita
Weigh South


Sartorius FC-Ex Series of Explosion-proof, Intrinsically Safe Scales
    sartorius industrial explosion proof balance       sartorius explosion scales
All models feature “isoTEST” - Fully automatic internal calibration.  At a touch of one key, the scale will calibrate itself automatically, using a built-in-weight.

Choice of safe or hazardous area power supply (must be ordered by scale)

IP54 Protection Rating

15 weighing applications standard

User friendly design with a backlit LCD display.

FC-Ex: FM Approved for use in Class 1, Division I, Groups A,B,C,D hazardous environments

              factory mutual approved balance
sartorius intrinsically safe scales

Standard Applications on
FC-Ex Scales

Toggle between two weight units

Counting

Weighing in Percent

Averaging (animal weighing)

Calculation (equation)

Density Determination

Differential Weighing

Checkweighing

Timer Functions

Totaling

Formulation

Statistics

300 Product Data Memory

User configurable printout

     
FC-Ex Display Features
Easy, User-Friendly Operation
The scale's display prompts the user in plain English for easy operator guidance.
The keyboard has large, clearly marked keys, which give you an instant tactile feedback.
 
sartorius explosion proof scale
Balance Information
  • 2 large tare keys for easy access for right and left hand users
  • 6 application defined soft-keys with the assigned function clearly shown in the graphic display above each key
  • SETUP key with “Windows” type menu and application selections
  • Key for toggling between up to 3 applications
  • ABC key allows for user input of alpha-numeric characters for user-defined headers and ID numbers
  • New graphic, back-lit LCD shows application related data and prompts the user through the selected application
 
What does Intrinsically Safe mean?
Through the use of special components, materials, ratings and component layouts, all electric circuits and inter-connected cables are designed sot that
       a) no spark or
       b) thermal effect is capable of causing ignition under fault conditions.

Intrinsically safe equipment can be isolated by Zener barriers from non-intrinsically-safe circuits for data transfer to the safe area
Basic principles of intrinsic safety:
• Voltage limitation
• Current limitation
• Limitation of storable energy
Advantages of intrinsically safe protection
• Equipment can be calibrated and maintained without removing power
• General purpose wiring methods can be used for connection to power
• No safety permits are required since the area does not need to be “shut down” for servicing

Classification of Hazardous Locations in the U.S.
Class
  Class I: Locations in which hazardous concentrations of flammable gases or vapors exist.
  Class II: Locations which are hazardous due to the presence of combustible or electrically conductive dust or fibers.
   
Division
  Division 1: Present continuously, intermittently or periodically under normal operating conditions.
  Division 2: Not present under normal conditions, but as a result of an equipment failure, breakdown of containers or abnormal operation of ventilating equipment.
Groups
  Group A: Atmospheres containing acetylene.
  Group B: Atmospheres containing hydrogen, gases or vapors of equivalent hazard, such as manufactured gas.
  Group C: Atmospheres containing ethyl ether vapors, ethylene or cyclopropane.
  Group D: Atmospheres containing gasoline, hexane, naptha, benzine, butane, propane, alcohol, acetone, benzol, lacquer solvent vapors or other natural gases.
Model
Readability
Weighing capacity
Pan size
(inches)
Response
time (s)
Repeatability
Linearity
Your Cost
FC06BBE-SX 0.001g
0.000002 lb
620 g
1.3 lb
5.1 1 0.001 g
0.000002 lb
0.002 g
0.000005 lb
See Price Here
FC2CCE-SX 0.01g
0.00002 lb
2,200 g
4.8 lb
8.5"x 7.9" 1 0.01 g
0.00002 lb
0.02 g
0.00005 lb
See Price Here
FC6CCE-HX 0.01g
0.00002 lb
6,200 g
13.6 lb
8.5"x 7.9" 1 0.01 g
0.00002 lb
0.02 g
0.00005 lb
See Price Here
FC6CCE-SX 0.1g
0.0002 lb
6,200 g
13.6 lb
8.5"x 7.9" 1 0.05 g
0.0001 lb
0.1 g
0.0002 lb
See Price Here
FC12CCE-SX 0.1g
0.0002 lb
12,000 g
26 lb
8.5"x 7.9" 1 0.05 g
0.0001 lb
0.2 g
0.0005 lb
See Price Here
*Power supply is always sold separately
Download the Installation and Operating Instruction Manual for the Sartorius FC Series for Hazardous Areas/Locations Manual (7.0MB) now download manual  You need Adobe Acrobat Reader to view.  The instruction manual contains detail information regarding calibration, additional features and keypad functions.
sartorius explosion proof scale
sartorius explosion proof balances
Dimensions of FC06BBE-SX in millimeters. 
Divide by 25.4 to convert to inches.
Dimensions of FC2CCE-SX, FC6CCE-HX, FC6CCE-SX,
FC12CCE-SX.  Divide by 25.4 to convert to inches.

family mutual approved balance
For those areas with ISO concerns the FC-EX scales are capable of transferring GLP/GMP compliant data via the RS232 interface.  User configurable printouts and calibration data can output to a printer or computer located outside the hazardous area through an optional Zener -Barrier (YDI02-Z, YDI03-Z)
Sartorius FC-Ex Explosion-Proof Balances
Download the User Manual (7.0 MB)


(select the model & any of the options to tooth right and then the "BUY HERE" image)

sartorius AGAccessories for FC-EX Scales
intrinsically safe industrial balance
YDI05-ZU2 Zener Barrier
$1099
zener barrier
YDI03-Z Zener Barrier (4x data lines, 4x control lines)
$1750
intrinsically safe scales
YTE02-X T-Connector
$850
intrinsically safe balance
YPE05-X Foot Switch
$670
explosion proof balances
YPS02-ZKR Safe area power supply (65 ft cable between scale and power supply)
$1925
explosion proof scales YPS02-XKR Hazardous area power supply
(8ft of intrinsically safe cable x 8ft cable requiring hardwiring by licensed electrician)
$2100
   
Cable, for connecting Sartorius accessories to FC series scales, 9.8 foot, 12-pin round (male) connector to 25 D-sub (female) connector YCC01-0016M3
$350
   
scale printer YDP20-OCE Data Printer with statistics and time/date functions, included cable fits RS232. (Requires the purchase of Zener barrier, YCC01-0016M3 Cable and 6971413 power supply to connect explosion proof balance to printer. Printer must be installed in Safe Area) YDP20-OCE
$999
6971413 power supply for YDP20-OCE Printer 6971413
$129
   
6960FB01 Base Dust Cover for FC06BBE-SX Explosion Proof Balance 6960FB01
$94
   
6960FB02 Base Dust Cover for FC2CCE-SX, FC6CCE-HX, FC6CCE-SX or FC12CCE-SX Explosion Proof Balance 6960FB02
$94
   
6960LP03 Dust Cover for display, fits all explosion proof scales 6960LP03
$94

Hot Buys | Analytical Balances | Baby Scales | Counting Scales | Industrial Platform & Bench Scales | Mechanical Balances
Moisture Balances | Pocket Scales | Portable Balances | Precision Toploader Balances | Price Computing Scales
Contact Us | Return Policy | Home | Calibration Weights | Sitemap

Have Questions? Call 978-521-7095 or e-mail us your questions and we will assist you in your selection.